• Skip to main content
  • Skip to footer

Valcourt Group

  • Services
    • Window Cleaning & Glass Restoration
    • Pressure Washing
    • ProXpress: Rapid Leak & Exterior Repairs
    • Waterproofing Services
    • Façade Restoration & Repair
    • Fall Protection Solutions
    • Additional Building Services
  • Locations
  • Industries
    • Commercial Real Estate
    • Apartments & Condominiums
    • Parking Structures
    • Facilities
    • Hospitality
    • Healthcare
    • Universities & 
Schools
    • Industrial Parks
    • Retail Buildings
    • Government & Municipality
    • Senior Living
    • Stadiums
  • Logo
  • About Us
    • About Us
    • Join The Valcourt Group
    • Careers
  • Insights
    • News
    • Blog
    • Resources
    • Projects
  • Contact Us
Search Btn

Second High Reservoir: Expansion Joint Repair and Urethane Injection

— The Valcourt Group | Oct 10, 2024

The Challenge

Located in Washington, DC., Second High Reservoir is a key component of the Washington Aqueduct, a water treatment and supply system that provides safe drinking water to roughly one million people in the DC area. Built in 1931, Second High Reservoir is a subsurface structure that is 24 feet deep and has a capacity of 15 million gallons.  

However, it was discovered that there was a considerable amount of water leaking both in and out of the tank. The U.S. Army Corps of Engineers, the entity that owns and operates the Washington Aqueduct, had no choice but to open a bidding process to repair and reseal the expansion joints inside the tank.  

Superior Grouting & Restoration Services (SGS) partnered with Norair Engineering Corp. to submit a bid. The pair won the contract with SGS as the grouting and concrete restoration subcontractor. 

The initial challenge SGS experienced was access— over 30 technicians were needed in the tank simultaneously. To ensure safe working conditions, SGS thoroughly planned and coordinated with all workers on site. 

The Solution

Once the project was underway, it was discovered that the on-site generator was not sufficient to operate all the tools and equipment. To remedy this, SGS supplied three of their own generators. 

Another difficulty was fighting off condensation where areas had been dried. It was a constant battle due to the substantial amount of water leaching into the tank. 

Ultimately, SGS completed over 23,000 linear feet of expansion joint repair, 12,000 linear feet of urethane injection, and overhead concrete spall repairs. The project was completed in 75 days— surpassing the deadline by one week— demonstrating the unwavering dedication of the SGS team.  

All parties involved, including the U.S. Army Corps of Engineers, their inspectors, and general contractor inspectors gave a resounding stamp of approval proving SGS’s success. As further evidence of the project’s success, SGS is now under contract for an even larger project with the client.  

Work Performed

  • Expansion Joint Repair 
  • Urethane Injection 
  • Concrete Spall Repairs 

Contact SGS For Your Specialty Grouting Needs

SGS specializes in a comprehensive range of structural and soil grouting services, concrete repair and restoration, concrete strengthening using Fiber Reinforced Plastic/Carbon Fiber (FRP) and other methods, and waterproofing for below-grade foundations.

With a reputation built on over half a century of experience, SGS is the right choice to ensure longevity and safety for your buildings or properties. For more information or to discuss your project needs, contact SGS here.

 

Popular Posts

Below-Grade Leak Sealing: The Smithsonian National Museum of African American History & Culture
Project Profiles, Waterproofing & Restoration

Below-Grade Leak Sealing: The Smithsonian National Museum of African American History & Culture

The Challenge Located on the National Mall in Washington DC, the Smithsonian's National Museum of African American History & Culture is the only museum dedicated to the documentation of African...

Read More
State-of-the-Art Safety Systems Installation
Project Profiles, Safety & Fall Protection

State-of-the-Art Safety Systems Installation

The Challenge Located in the Penn Quarter neighborhood of Washington DC, this former media museum was acquired by our client in 2019. Soon after, the owners embarked on a massive,...

Read More
Rooftop Tent Tieback Anchor Installation at Marina Hotel
Project Profiles

Rooftop Tent Tieback Anchor Installation at Marina Hotel

The Challenge Valcourt Safety Systems (VSS) was hired by our client to install tent anchor tiebacks on their rooftop. After numerous delays due to client revisions of the design, the...

Read More

ABOUT US

  • About Us
  • Join The Valcourt Group
  • Careers
  • News
  • Blog
  • Resources

SERVICES

  • Window Cleaning & Glass Restoration
  • Pressure Washing
  • ProXpress Rapid Leak & Exterior Repairs
  • Waterproofing Services
  • Façade Restoration & Repair
  • Fall Protection Solutions
  • Additional Building Services

INDUSTRIES

  • Commercial Real Estate
  • Apartments & Condominiums
  • Parking Structures
  • Facilities
  • Hospitality
  • Healthcare
  • Universities & Schools
  • Industrial Parks
  • Retail
  • Government & Municipality
  • Stadiums

Contact Us

dashicons-phone 1-800-222-9533
dashicons-email [email protected]

dashicons-linkedin dashicons-facebook-alt

  • Privacy Policy
  • Applicant & Worker Privacy Notice
  • Web Accessibility
  • Site Map
  • Personal Data Request

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service app.